H06.25 Software Installation and Upgrade Guide

4. Click Yes. The CLIM reboots.
5. If the system disk is a SAS disk and you have SAS disk enclosures that contain the system disks
(both primary and mirror), issue the following command on one of the storage CLIMs that
connect to the system disks:
lunmgr ––approve yesall
6. For the maintenance provider CLIMs, configure the maintenance provider interface:
a. For the two IP CLIMs configured with a Maintenance Provider (usually the first two IP
CLIMs, for example, N100251/N100252), configure the eth0:0 interface. Using the IP
address and netmask of ZTCP0 and ZTCP1 you collected by using the SCF INFO CLIM
DETAIL and CLIMCMD climconfig interface -info commands (
climcmd climname climconfig interface -info eth0:0
) prior to starting the downgrade, and using the iLO serial console, enter these commands
at the Linux prompt:
climconfig interface -add eth0:0
climconfig ip -add eth0:0 -ipaddress 192.168.36.10 -netmask 255.255.0.0
NOTE: The ipaddress and netmask values in the above command are examples,
and these are provided by the CLIMCMD climconfig interface -info commands; however,
eth0:0 is a hard-coded value for the CLIMs.
7. When you receive the Remote disconnected without sending a disconnect
message, click Ok.
144 Falling Back on the CLIMs, Loading the Previous RVU, and Resuming Normal Operations