H06.25 Software Installation and Upgrade Guide

h) Click OK when asked β€œAre you sure you want to do a Power Cycle All
Processors?”
i) When the Action Status box confirms that the power cycle has successfully
completed, close the dialog box.
NOTE: It should take approximately five minutes for all processors to complete
Power On initialization.
3) Load (coldload) the system with the RVU to which you are reverting.
c. Update NonStop Blade Complex (NSBC) firmware on the other flash, as follows:
1) Using the OSM Service Connection and the Blade Complex Firmware Update guided
procedure, complete the dialog boxes and update the shadow firmware on each
NonStop Blade Element.
NOTE: In the Select Firmware Modules for shadow image dialog box, select all
parts that are noted as Up-Rev, except for BMC firmware (T0661); you must not
revert to previous BMC firmware (see Support Note S08016).
2) Using the Switch Blade Element Firmware Images dialog box, select NO.
3) Repeat steps 1 and 2 for the other NonStop Blade Complexes.
Install Specific OSS Files (If Necessary)
For those products that are not managed by DSM/SCM, you must install them using COPYOSS
or PINSTALL or both. For details, see β€œInstall Specific OSS Files Using COPYOSS or PINSTALL”
(page 124).
NOTE: Features introduced in H06.23 affect the default security settings in OSS. See Support
Note S12018 for detailed information.
Verify That the System Is Started
Verify that each processor is running the operating system:
1. From the Summary menu in the OSM Low-Level Link, select Processor Status.
2. The Processor Status dialog box should show each processor to be Executing NonStop OS.
152 Falling Back on the CLIMs, Loading the Previous RVU, and Resuming Normal Operations