H06.25 Software Installation and Upgrade Guide

system. Once the objects have been properly constructed on the G-series RVU system, they
can be moved to the H-Series or J-series RVU system by whatever means preferred, for example,
by Expand, FTP, or magnetic tape. For more details, refer to the H-Series Application Migration
Guide.
T6031G01^ABP provides the option to use DSM/SCM to manage software in an environment
composed of systems running different RVU series. The systems need not be connected through
Expand. For more details, see the NonStop Software Essentials User's Guide.
T9617G03^AAY allows you to check the VPROC of H-series and J-Series object files that
have been copied to a G-series RVU system or in situations where a G-series RVU node is
used to manage software for a H-series or J-series RVU system. This functionality can also be
used to query the VPROC of a remote object file through Expand.
Table 14 SPRs for Software Migration and Software Management Operations Between G-Series,
H-Series and J-Series RVU-Based Systems
Introduced in this RVUDescriptionProduct NameMinimum SPR
G06.27Required to recognize 800 filesVPROCT9617G03^AAY
G06.27Required to recognize OCA regionBinderT9621D30^ABB
G06.27Required to recognize OCA regionPDTSHARET9674D30^AAM
G06.27Required to recognize OCA regionAxcelT9276D30^AAW
G06.27Required to prepare TNS code files to run
accelerated on a NonStop NS-series
platform
OCAT0448G06^AAA
Released post G06.26
and is backwards
Required to enable receiving H-series SUTs
and installing and managing software on
DSM/SCMT6031G01^ABP
compatible to G06.21.a NonStop NS-series target system from a
Also, the G02 SPRNonStop S-series host (available to be
(installed with G06.27applied to the G06.26 RVU and
and later) meets the
requirements.
compatible to G06.21). The functions in
T6031ABP and T9298AAM are included
in the G02 DSM/SCM and SWID product
version updates released in G06.27 and
later G-series RVUs.
With SQL/MX 2.3.4 installed on any node in a mixed-node environment, accessing any MX or
MP objects on a J or H-Series “downrev node” will fail with errors 1002 and 1100/1102/1103.
If T1050H23^AMC (SQL/MX MXCMP) and T0611H23^AMC (SQL/MX MODULES) are installed
over SQL/MX 2.3.4, then accessing MX and MP objects on G-Series “downrev node” will fail
with error 8016. A “downrev node” is any node running SQL/MX versions 2.3.3 or lower. To
prevent this, install these SPRs on all H-series RVUs less than or equal to H06.20:
T1050H23^AMN (SQL/MX MXCMP)
T0611H23^AML (SQL/MX MODULES)
NOTE: See Hotstuff HS03051 for more information.
Table 15 H-Series and J-Series RVUs Needing SPRs for Nodes to Interoperate with SQL/MX 2.3.4
(H06.20 and Later RVUs)
J-SeriesH-Series
J06.03 J06.04.00 J06.04.01 J06.04.02 J06.05.00
J06.05.01 J06.06.00 J06.06.01 J06.06.02 J06.07.00
J06.07.01 J06.08 J06.09
H06.10.00 H06.10.01 H06.11.00 H06.11.01
H06.11.02 H06.11.03 H06.12 H06.13 H06.14
H06.15.00 H06.15.01 H06.15.02 H06.16.00
H06.16.01 H06.17.00 H06.17.01 H06.17.02
H06.18.00 H06.18.01 H06.19 H06.20
76 Preparing to Upgrade the Server Software (Pre-installation Tasks)