H06.25 Software Installation and Upgrade Guide

F1-Select
F15-Help F16-Return SF16-Exit
Ready
5. Enter 3 (Review operator instructions for the last apply completed) in the Selection number
field, and press F1 to display the operator instructions.
6. Enter a printer location in the Print operator instructions field, and press F9 to print the operator
instructions.
An example instruction screen might look like this:
Activation Instructions for \BITDRP BITDRP
These are general instructions that were determined from configuration
attributes. Refer to the release documentation for detailed information
on migrating to this software configuration.
1. Stop all applications. Keep OSS running.
2. RUN ZDSMSCM.ZPHIRNM SYS01
(Note: replace nn with correct number)
3. Check for $0 EMS messages.
Correct any errors indicated in the $0 EMS messages.
Do not proceed until this step has been successfully completed.
4. Coldload is required.
5. Run merge_whatis if ZPHIRNM indicates it is needed.
6. Update FIRMWARE.
Run OSM (or TSM) to check firmware and perform firmware updates.
T2805 MAINTENANCE ENTITY includes firmware changes.
T2805 MAINTENANCE ENTITY includes firmware changes.
T0287 HSS - Halted State Services includes firmware changes.
T0630 FCSA F/W includes firmware changes.
T0287 PRM - Primitive State includes firmware changes.
T0287 IPF - Itanium(tm) Processor Firmware includes firmware changes.
7. Restart all applications.
7. Press SF16 to exit the Target Interface.
In the Activation instructions, you might see information regarding the merge_whatis OSS
command:
Run merge_whatis if zphirnm indicates it is needed.
When you finally run ZPHIRNM, the following lines are written to the log:
Note: merge_whatis needs to be run to update the man pages. Files in a whatis.frag directory have changed.
The merge_whatis is a shell script in /bin. It creates and updates the whatis database used
by the OSS shell man, apropos, and whatis commands. You must run the merge_whatis
command once against each directory that contains the man page files to be used.
You will run merge_whatis after using ZPHIRNM. If you have OSS configured to run the OSS
merge_whatis utility automatically, you can ignore running merge_whatis.
Recovery for Problems Installing This RVU SUT or SPRs
If you receive an error indication in the Requests, Status, or EMS Events windows, you might have
to reinitiate the Build/Apply. See the DSM/SCM Messages Manual to determine the nature and
severity of the problem.
Cancel Pending Build/Apply Requests
NOTE: If you inadvertently navigate away from the Status page, reopen it by clicking on the
Request Name link on the Request List page.
Click the Cancel button.
Recovery for Problems Installing This RVU SUT or SPRs 89