H06.27 Software Installation and Upgrade Guide

7. (Optional) Confirm that the Spooler is active and not 100 percent full before executing the
Build/Apply request. At a TACL prompt, start SPOOLCOM and issue a COLLECT, STATUS
command. For example:
12> spoolcom $spls; collect, status
COLLECT STATE FLAGS CPU PRI UNIT DATA FILE %FULL
$S ACTIVE 3 , 1 154 4 $OPS0.SPL.DATA 4
8. In the Build/Apply Request page, click Submit Build/Apply.
DSM/SCM runs the Build and Apply steps and displays a Status window, which is automatically
updated every five seconds. For example:
9. Check EMS messages for more detailed information about your Build/Apply.
Click the system name in the System column to view EMS events on that system for this
Build/Apply request.
When the Build/Apply finishes successfully and a snapshot is received into the host database:
The Request activity summary in the Status window shows that the Build, Apply, Create
snapshot, and Receive snapshot activities finished. For example:
90 Installing a SUT for This RVU Using NonStop Software Essentials