J06.07 Software Installation and Upgrade Guide

These specific SPRs must be installed on systems running G-series RVUs for compatibility and
interoperability through a ServerNet Cluster with systems running J-Series RVUs.
Table 14 Interoperability SPRs for G-Series RVU Systems Connected through ServerNet to J-Series
RVU Systems
Introduced in this RVUDescriptionProduct NameMinimum SPR
G06.31Required for ServerNet clustering*SNETMONT0294G08^AAX
G06.31Required for ServerNet clustering*SANMANT0502G08^AAX
G06.25Required for ServerNet clustering*OSM Service
Connection Suite
T0682G06^AAA
*For more details, see the ServerNet Cluster Supplement for HP Integrity NonStop BladeSystems. To find out if your
NonStop server supports ServerNet clustering, see the planning guide for your NonStop server.
These SPRs must be installed on systems running G-Series RVUs for compatibility and interoperability
through a ServerNet Cluster with systems running H-Series RVUs.
Table 15 Interoperability SPRs for G-Series RVU Systems Connected through ServerNet to H-Series
RVU Systems
Introduced in this RVUDescriptionProduct NameMinimum SPR
G06.26Required for ServerNet clustering*SNETMONT0294G08^AAP
G06.26Required for ServerNet clustering*SANMANT0502G08^AAN
G06.25Required for ServerNet clustering*OSM Service
Connection Suite
T0682G06^AAA
*For more details, see the ServerNet Cluster Supplement for NonStop NS-Series Servers. To find out if your NonStop
server supports ServerNet clustering, see the planning guide for your NonStop server.
These SPRs facilitate software migration and software management operations between nodes
running G-series RVUs and nodes running H-series and J-series RVUs:
The T9621D30^ABB, T9674D30^AAM, T9276D30^AAW, and T0448G06^AAA SPRs
provide the option of using a G-series RVU system to construct objects that will ultimately run
on an H-series or J-series RVU system. Possible activities that can be performed in the G-series
RVU system include accelerating objects that will eventually run on an H-Series or J-series RVU
system. Once the objects have been properly constructed on the G-series RVU system, they
can be moved to the H-Series or J-series RVU system by whatever means preferred, for example,
by Expand, FTP, or magnetic tape. For more details, please refer to the H-Series Application
Migration Guide.
T6031G01^ABP provides the option to use DSM/SCM to manage software in an environment
composed of systems running different RVU series. The systems need not be connected through
Expand.
T9617G03^AAY allows you to check the VPROC of H-series and J-Series object files that
have been copied to a G-series RVU system or in situations where a G-series RVU node is
used to manage software for a H-series or J-series RVU system. This functionality can also be
used to query the VPROC of a remote object file through Expand.
Table 16 SPRs for Software Migration and Software Management Operations Between G-Series,
H-Series and J-Series RVU-Based Systems
Introduced in this RVUDescriptionProduct NameMinimum SPR
G06.27Required to recognize 800 filesVPROCT9617G03^AAY
G06.27Required to recognize OCA regionBinderT9621D30^ABB
Install Node Interoperability SPRs 49