J06.08 Software Installation and Upgrade Guide
Table Of Contents
- J06.08 Software Installation and Upgrade Guide
- Contents
- About This Document
- 1 Overview of Installing This RVU
- SUT on DVD
- CLIM Software for This RVU
- Disk Space Requirements
- Operational Differences Between This RVU and H-series RVUs
- Investigating a J-Series RVU
- System Console Requirements
- Using OSM With This RVU
- Using DSM/SCM and NonStop Software Essentials With This RVU
- NonStop Software Essentials and This RVU
- DSM/SCM and This RVU
- DSM/SCM and Public DLLs
- DSM/SCM and OSS
- Upgrading the NonStop Software Essentials Client
- Upgrading the DSM/SCM Client (Planner Interface) and the T6031H02 PVU
- Summary of Software Installation Tasks
- Check or Alter the CONFTEXT File Before Installing This RVU SUT
- Installing CLIM Software
- Backing Out the DSM/SCM Revision
- Managing Microcode and Firmware
- Installation, Migration, and Fallback
- 2 Managing Microcode and Firmware
- Managing ME Firmware and ME FPGA Firmware
- Managing OA Firmware for the c7000 Enclosure
- Managing Server Blade Firmware
- Managing ServerNet Adapter Firmware
- Managing SWAN and SWAN 2 Concentrator Firmware
- Managing NonStop Cluster Switch Firmware
- Managing CLIM Firmware
- Managing S-Series Interoperability Firmware
- 3 Installation, Migration, and Fallback Considerations for This RVU
- 4 Upgrade Checklist
- 5 Preparing to Upgrade the Server Software (Preinstallation Tasks)
- Back Up Important Files
- Record the Current SYSnn
- Save the Current Configuration File (CONFxxyy)
- Verify System Processes
- Check Processor Status
- Check System Components
- Verify the State of the Internal ServerNet Fabric
- Verify Firmware
- Verify Critical System Processes
- Verify Disk Drives
- Verify Tape Drives (If Necessary)
- Verify That the CLIMs Are in the Started State
- Verify That the CIP Providers Are in the Started State
- Check the Status of the Spooler Collector
- Check for Sufficient Swap File Space
- Install Node Interoperability SPRs
- Back Up System Information
- Manually Install the NonStop Software Essentials Server Product
- 6 Installing a SUT for This RVU Using NonStop Software Essentials
- 7 Installing a SUT for This RVU Using the Planner Interface
- 8 Running ZPHIRNM
- 9 Loading This RVU
- 10 Resuming Normal Operations
- Revive the Down Half of the Mirrored Disk
- Validate Your Core License
- Start System Applications
- Run merge_whatis
- Configure Specific Products (Post-System Load)
- 11 Backing Out the DSM/SCM Revision
- 12 Running ZPHIRNM to Reactivate the Previous Software Revision
- 13 Falling Back on the CLIMs, Loading the Previous RVU, and Resuming Normal Operations
- Fallback Considerations for the Power Regulator
- Alerts
- Task Overview
- Before Halting the Processors
- Halt the Processors
- While the Processors are Halted
- Prepare the CLIMs
- Load the System
- Complete CLIM Setup
- Revert Firmware (If Necessary)
- Install Specific OSS Files (If Necessary)
- Verify That the System Is Started
- A Using DSM/SCM and NonStop Software Essentials to Install SPRs
- B Using DSM/SCM and Planner Interface to Install SPRs
- C Installing SWID and DSM/SCM PVU Using NonStop Software Essentials Client Software
- Alerts
- Copy (RESTORE) the H02 DSM/SCM Product Version to Disk (If Necessary)
- Receive the H02 SWID and DSM/SCM SPRs
- Create a New Software Revision for H02 DSM/SCM and SWID SPRs
- Build and Apply the DSM/SCM H02 Software Product Revision
- Run the INSTALL^TEMPLATES Macro
- Restart Applications
- Recovery for Problems While Installing the H02 Version of DSM/SCM
- Install the NonStop Software Essentials Client
- Install the NonStop Essentials Client From the HP Insight Control for NonStop DVD
- D Installing SWID, DSM/SCM PVU, and Planner Interface (PI) Client Software
- Alerts
- Copy (RESTORE) the H02 DSM/SCM Product Version to Disk (If Necessary)
- Receive the H02 SWID and DSM/SCM SPRs
- Create a New Software Revision for H02 DSM/SCM and SWID SPRs
- Build and Apply the DSM/SCM H02 Software Product Revision
- Rename the Applied DSM/SCM H02 Files By Running ZPHIRNM
- Run the INSTALL^TEMPLATES Macro
- Restart Applications
- Recovery for Problems While Installing the H02 Version of DSM/SCM
- Install the DSM/SCM Client From ZDSMSCM
- E Updating SWAN Concentrator CLIP Firmware
- Acronyms
- Index

• A note was added to the CLIMRSTR step of “Complete CLIM Setup” (page 129).
• The order of steps for resetting and starting the disks changed in “Complete CLIM Setup”
(page 129) for the case of no LUNs started during the CLIM reboot (step 3d).
The 584300-008 edition contained this change: Step 3 in “Complete CLIM Setup” (page 129) was
revised to include the need for rebooting Storage CLIMs after executing the clearlog command.
The 584300-007 edition contained this change: The privileges required for running SSOCLIM
changed back to any SUPER group user. See “Complete CLIM Setup” (page 129).
The 584300-006 edition contained these changes:
• In “Configure the WAN Manager” (page 98), references to either the SWAN Concentrator
Installation and Support Guide or the SWAN 2 Concentrator Installation and Support Guide
replaced procedures.
• Considerations were added to the J06.08 section of Chapter 3: “Installation, Migration, and
Fallback Considerations for This RVU” (page 31).
• In “Updating SWAN Concentrator CLIP Firmware” (page 168), the procedural information was
deleted and replaced with references to either the SWAN Concentrator Installation and Support
Guide or the SWAN 2 Concentrator Installation and Support Guide.
• In Appendix C: “Installing SWID and DSM/SCM PVU Using NonStop Software Essentials
Client Software ” (page 147), the Create an Emergency Repair Disk (ERD) or Automated System
Recovery (ASR) Disk section was deleted.
The 584300-005 edition contained this change: In “Managing Server Blade Firmware” (page 25),
NonStop NS2000 series servers information was added.
The 584300-004 edition contained these changes:
• Most firmware levels have been moved to the NonStop Firmware Matrices document.
• An important warning was added to the note in “Run the inetd Process” (page 97).
These changes were made to clarify CLIM software upgrade:
• Chapter 3: “Installation, Migration, and Fallback Considerations for This RVU” (page 31) was
changed to correct the CLIM interoperability issues that apply to J06.05 and J06.06 and later
J-series RVUs.
• Chapter 4: “Upgrade Checklist” (page 36) was changed to eliminate a CLIM reboot step after
the software upgrade step because the reboot occurs during the software update procedure
itself and was therefore redundant as a separate step in the checklist. This section also mentions
that for J06.06 and later RVUs, the CLIMs can be updated online, in advance of the RVU
software installation, and that the steps must be performed in order. Finally, the contingency
that you may have already performed the CLIM software upgrade online before beginning
the RVU upgrade is accounted for in the steps.
• Chapter 4: “Upgrade Checklist” (page 36) was reorganized to make it clear that for an offline
upgrade of CLIMs, you perform the CLIM software upgrade while the processors are halted.
As part of this clarification, “4. Upgrade the CLIM Software” (page 87), was made into a
distinct step.
New and Changed Information in Previous Editions 11