J06.10 Software Installation and Upgrade Guide
Table 13 Upgrade Checklist (continued)
Done?ReferenceTask Description
8. Install and configure the latest
Halted State Services firmware, if
• NonStop System Console (NSC) Installer Guide
(procedures)
necessary (includes DISKBOOT and
• NonStop Firmware Matrices (firmware levels
reference)
ISP1040 firmware). Note: This step
is not applicable to NonStop
NS2000 series systems.
“Verify System Processes” (page 42)9. Verify system operations.
Cluster I/O Protocols (CIP) Configuration and
Management Manual (installation procedures), CLuster
10. Install CLIM software on NonStop
System Console.
I/O Module (CLIM) Software Compatibility Reference
(CLIM software and firmware compatibility information)
“Receive New Software Into the Archive” (page 52)11. For those with NonStop Software
Essentials, receive the RVU SUT into
the DSM/SCM software archive.
“Receive New Software Into the Archive” (page 64)12. For those with the DSM/SCM
Planner Interface, receive the RVU
SUT into the DSM/SCM software
archive.
“Create a New Software Revision” (page 55)13. For those with NonStop Software
Essentials, create the RVU software
configuration revision.
“Create a New Software Revision” (page 68)14. For those with the DSM/SCM
Planner Interface, create the RVU
software configuration revision.
“Build and Apply the New Software Revision” (page 58)15. For those with NonStop Software
Essentials, build and apply the RVU
software revision.
“Build and Apply the New Software Revision” (page 71)16. For those with the DSM/SCM
Planner Interface, build and apply
the RVU software revision.
“Print Operator Instructions From the Target Interface
(ZPHITI)” (page 60)
17. Print DSM/SCM Operator
Instructions.
Chapter 8: “Running ZPHIRNM ”18. Run ZPHIRNM.
“2. Halt the Processors” (page 89)19. Halt the processors.
“4. (Conditional): Update the HSS Firmware” (page 90)20. If Halted State Services firmware
is being upgraded, hard reset the
processors. Note: This step is not
applicable to NonStop NS2000
series systems except that a reset is
required if upgrading to J06.14 or
a later RVU. Also, if you performed
step 16 on any other NonStop
system running J-series software (i.e.,
updating system firmware using HP
SUM), a power cycle has occurred
and hard resetting the processors
again is not necessary.
This update is done through a Field Change Order
(FCO).
21. Update c7000 Enclosure
firmware, if necessary.
“5. (Required Only for Upgrade from J06.13 or Earlier
to J06.14 or Later) Perform a Hard Reset” (page 91)
22. Reset the system firmware if you
are upgrading to J06.14 or a later
RVU.
38 Upgrade Checklist