J06.12 Software Installation and Upgrade Guide
◦ If the CCSA firmware attributes show that the current firmware Version is the same as the
available Default File Version; no update is necessary. If the Compare State was Down-rev,
you would use the Firmware Update action to update the firmware.
◦ For more information about the CCSA, refer to the LAN Configuration and Management
Manual. See also “Managing S-Series Interoperability Firmware” (page 28) and the
NonStop Firmware Matrices.
• TRSA. TRSAs in a NonStop S-series I/O enclosure provide token-ring connectivity to NonStop
BladeSystems via IOMF2 CRU to c7000 ServerNet switch connections.
◦ To add or start the TRSA, use the SCF interface to the SLSA subsystem.
◦ To check and update the TRSA firmware, use the TSM Service Application as described
in the Token-Ring Adapter Installation and Support Guide. For more information, refer to
the LAN Configuration and Management Manual
Table 7 (page 27) identifies the FCSA, G4SA, and CCSA firmware product names and their latest
T-number and firmware levels.
Table 7 J-Series ServerNet Adapters Firmware Information
Latest NonStop T-Number and Firmware LevelFirmwareServerNet Adapter
T0630G06^AAUFCSA flash firmwareFibre Channel ServerNet Adapter
(FCSA)
T0612G06^AABFCSA Flash Boot firmwareFibre Channel ServerNet Adapter
(FCSA)
T0613G06^AASG4SA Boot firmwareGigabit Ethernet 4-Port ServerNet
Adapter (G4SA)
T0309G08^AAFSS7 firmware6373 Common Communication
ServerNet Adapter (CCSA)
Managing SWAN and SWAN 2 Concentrator Firmware
Both SWAN and SWAN2 are supported in J-series RVUs, and OSM is used to update the firmware.
SCF can also be used. For procedures to update the firmware, see either the SWAN Concentrator
Installation and Support Guide or the SWAN 2 Concentrator Installation and Support Guide.
NOTE: Firmware levels for each component are located in the NonStop Firmware Matrices
document.
Managing NonStop Cluster Switch Firmware
To monitor and manage a ServerNet Cluster product configured with 6780 switches, use either
the OSM Service Connection or SCF commands. See the ServerNet Cluster 6780 Operations
Guide for more information.
For information on required software, installation, migration, and fallback procedures, see the
ServerNet Cluster 6780 Planning and Installation Guide.
NOTE: Check with Scout for the latest SPRs. For firmware levels, see the NonStop Firmware
Matrices located in the Service Information section of the Support and Service collection of the
NonStop Technical Library at www.hp.com/go/nonstop-docs.
Managing SWAN and SWAN 2 Concentrator Firmware 27