Table 13 Upgrade Checklist (continued)
Done?ReferenceTask Description
6. Install required or recommended
fallback SPRs and node
interoperability SPRs, if necessary.
“Using DSM/SCM With NonStop Software Essentials
to Install SPRs” (page 128) (procedure)
“Using DSM/SCM With the Planner Interface to Install
SPRs” (page 135) (procedure)
“Install Node Interoperability SPRs” (page 50) (list of
required SPRs)
“Updating System Consoles (Optional)” (page 15)7. Upgrade system console software.
8. Install and configure the latest
Halted State Services firmware, if
NonStop System Console (NSC) Installer Guide
(procedures)
necessary (includes DISKBOOT and
NonStop Firmware Matrices (firmware levels reference)
ISP1040 firmware). Note: This step
is not applicable to NonStop
NS2000 series systems.
“Verify System Processes” (page 44)9. Verify system operations.
Cluster I/O Protocols (CIP) Configuration and
Management Manual (installation procedures), CLuster
10. Install CLIM software on NonStop
System Console.
I/O Module (CLIM) Software Compatibility Reference
(CLIM software and firmware compatibility information)
“Receive New Software Into the Archive” (page 54)11. For those with NonStop Software
Essentials, receive this RVU SUT into
the DSM/SCM software archive.
“Receive New Software Into the Archive” (page 66)12. For those with the DSM/SCM
Planner interface, receive this RVU
SUT into the DSM/SCM software
archive.
“Create a New Software Revision” (page 57)13. For those with NonStop Software
Essentials, create this RVU software
configuration revision.
“Create a New Software Revision” (page 70)14. For those with the DSM/SCM
Planner Interface, create this RVU
software configuration revision.
“Build and Apply the New Software Revision” (page 60)15. For those with NonStop Software
Essentials, build and apply this RVU
software revision.
“Build and Apply the New Software Revision” (page 73)16. For those with the DSM/SCM
Planner Interface, build and apply
this RVU software revision.
“Print Operator Instructions From the Target Interface
(ZPHITI)” (page 62)
17. Print DSM/SCM Operator
Instructions.
Chapter 8: “Running ZPHIRNM ”18. Run ZPHIRNM.
“2. Halt the Processors” (page 91)19. Halt the processors.
“3. (Conditional): Update the System Firmware” (page 92)20. (Optional) Update system
firmware using HP SUM(this applies
to all NonStop systems running
J-series software except the NS2000
series, but is not always required).
“4. (Conditional): Update the HSS Firmware” (page 92)21. If Halted State Services firmware
is being upgraded, hard reset the
processors. Note: This step is not
applicable to NonStop NS2000
series systems except that a reset is
Upgrade Checklist 39