J06.13 Software Installation and Upgrade Guide
NOTE: In the OSM Low-Level Link, a G16SE enclosure is shown as a VIO module. In the OSM
Low-Level Link, a VIO or G16SE logic board is represented as an IME object.
To use the OSM Service Connection to update the ME firmware for VIO and G16SE enclosures:
1. Locate the VIO Logic Board: in the tree pane, select one of, depending on the type of server:
• System > Fabric Group > Internal ServerNet Fabric > VIO Module > VIO Logic Board.
or
• System > Group
nnn
> VIO Module > VIO Logic Board
2. Right-click the VIO Logic Board object and select Actions.
3. In the Actions dialog box, select ME Firmware Update and click Perform Action.
4. Monitor the update.
5. Repeat for the VIO or G16SE enclosure in the other fabric.
Updating ME FPGA
NOTE: For firmware levels, see the NonStop Firmware Matrices document, located in the Service
Information section of the Support and Service collection of the NonStop Technical Library at
www.hp.com/go/nonstop-docs.
Table 3 Maintenance Entity (ME) FPGA File Names and Locations
Default LocationFile NameComponentFirmware Name
SYSnnSAM0815ServerNet Switch (c7000
enclosure)
ME FPGA (see Caution
below)
SYSnnSAM0437ServerNet Switch (IOAM
enclosure)
ME FPGA (see Caution
below)
SYSnnSAM0789VIO enclosure logic boardME FPGA for IME in G16SE
enclosures and VIO
enclosures (see Caution
below)
CAUTION: You should not use the Multi-Resource Actions dialog (in the OSM Service Connection)
to update ME FPGA simultaneously on both fabrics, or a system outage might occur.
Use the OSM Service Connection to check and (if necessary) update the ME FPGA for all c7000,
G16SE, and VIO enclosures and IOAMs just as you did when updating ME firmware, but choose
the ME FPGA Update action instead.
For information on using the OSM Low-Level Link to update ME FPGA, see the online help available
within the application.
Managing OA Firmware for the c7000 Enclosure
Check the NonStop Firmware Matrices document for the minimum supported OA firmware for
this release.
Managing Server Blade Firmware and Blade Element Firmware
NOTE: For minimum firmware levels for this RVU, see the NonStop Firmware Matrices document.
24 Managing Microcode and Firmware