J06.14 Release Version Update Compendium

Results are unpredictable if a program calling these new BINSEM routines is compiled on a J06.14,
system and run on a system with an RVU earlier than J06.14,
For more information about these new BINSEM features, see the Guardian Procedure Calls Reference
Manual in the NonStop Technical Library.
Migration Considerations
None.
Fallback Considerations
The binSemStats_t structure and the BINSEM_STAT_VERSION_ and BINSEM_GETSTATS_
procedures are version sensitive. Results are unpredictable if a program calling these new BINSEM
routines is compiled on a J06.14, system and run on a system with an RVU earlier than J06.14,
NOTE: The SEMSTAT utility is provided with the operating system, and if it is run on a J06.14,
system it works with no issues. However, if the utility is run on a J-series RVU earlier than J06.14,
it exits with an error message.
NonStop Binary Semaphores (BINSEM) 13