NonStop Firmware Matrices
Minimum Supported OA Firmware Levels for NonStop
BladeSystems
The following table identifies the minimum supported OA firmware level for each type of NonStop
BladeSystem.
CAUTION: “NonStop Supported Levels for J06.04–J06.17 and H06.15–H06.28 for Firmware
Not Delivered on the SUT ” (page 12) lists all of the OA firmware levels qualified for use on
NonStop systems. The following table is intended to identify the minimum supported OA firmware
version within the set of levels qualified for use on NonStop systems. Not every subsequent OA
firmware level is immediately qualified for use on NonStop systems.
IMPORTANT: If an OA firmware update is required, the highest numbered version listed in
“NonStop Supported Levels for J06.04–J06.17 and H06.15–H06.28 for Firmware Not Delivered
on the SUT ” (page 12) should be used, except for conditions described in the following notes:
NOTE: OA FW version 3.60 requires either J06.16 or later or OSM SPR T0682ADF or later for
RVUs older than J06.16. If the RVU is not J06.16 or later or if OSM SPR T0682ADF or later is not
installed for RVUs older than J06.16, then OA FW version 3.31 or older should be used. Use of
OA FW version 3.60 on RVUs older than J06.16 without OSM SPR T0682ADF or later will cause
an OSM alarm for a single sign-on failure. For details, please refer to Support Note S13001.
NOTE: OA FW version 4.01 requires either J06.17 or later or OSM SPR T0682ADH or later
for RVUs older than J06.17. If the RVU is not J06.17 or later or if OSM SPR T0682ADH or later
is not installed for RVUs older than J06.17, then OA FW version 3.60 or older should be used.
Use of OA FW version 4.01 on RVUs older than J06.17 without OSM SPR T0682ADH or later
will cause an OSM alarm for a single sign-on failure.
Minimum Supported OA Firmware VersionNonStop BladeSystem Type
2.25 or 2.52
1
NB50000c, NB50000c-cg
3.21NB54000c, NB54000c-cg
3.60NB56000c, NB56000c-cg
1
Minimum version depends on the OA module part number. See “NonStop Supported Levels for J06.04–J06.17 and
H06.15–H06.28 for Firmware Not Delivered on the SUT ” (page 12).
56 Minimum Supported OA Firmware Levels for NonStop BladeSystems