NonStop Firmware Matrices

server flash memory. See the WARNING below regarding actions during the write of the
firmware to flash memory.
If Reboot to activate is postponed, additional user actions are required to power off and power
on the server after exiting HP SUM.
WARNING! The Locator UID LED is also shown on the iLO web interface Virtual Front Panel.
While the Locator UID LED is flashing, do not disconnect power to the server. If the power is
removed, the server flash memory might become corrupted. If flash memory corruption occurs,
the system board in the server might need to be replaced.
7. If HP SUM was run with Reboot to activate postponed, the following additional steps are
required:
a. In OSM Low Level Link, halt the processor on the server that was updated.
b. Open an iLO web interface to the server that was updated.
c. In the iLO Status Summary screen, click the Press & Hold button, then confirm to power
off the server.
When the server is powered off, the new system firmware is written to the server flash
memory. This process takes up to 15 minutes to complete. Do not remove power to the
server during the write process. See the WARNING above for possible consequences of
these actions.
d. After the write of the firmware to flash memory is completed, click the Momentary Press
button to power on the server. To activate the iLO web interface, you might need to
re-enter the iLO login credentials.
8. After the server reboots on the new firmware, the processor reappears in OSM Low Level Link
with the PON No OS image (Halt %100212) status. The processor can then be
reloaded.
Updating rx2800 i2 Server Firmware
IMPORTANT: Hotstuff HS03181E requires all NS2200, NS2200T, NS2200ST, and NS2100
system servers to be updated with rx2800 i2 server firmware bundle version 26.34 or later.
HS03181E provides several options for updating the firmware on all the servers in an NS2200,
NS2200T, NS2200ST, and NS2100 system. If all servers in an NS2200, NS2200T, NS2200ST,
and NS2100 system are being updated, see HS03181E for the options and instructions. This
section provides instructions to update the firmware on a single rx2800 i2 server.
1. Click the link to the selected firmware version for rx2800 i2 server located in NonStop
Supported Levels for J06.04–J06.17 and H06.15–H06.28 for Firmware Not Delivered on
the SUT (page 12).
If this link is invalid, follow the steps described in “Using the HP Business Support Center or
the HP Support Center to Download Firmware Components Not Delivered on the SUT”
(page 76).
NOTE: To update the server firmware in NS2200, NS2200T, NS2200ST, and NS2100
systems, download the system firmware bundle type titled “Firmware System with version
numbers 26.xx.
2. On the firmware download web page, click the Installations Instructions tab. For reference
during the firmware update, copy or print the instructions.
For more information about the HP SUM tool, see the HP SUM User Guide:
http://h18004.www1.hp.com/products/servers/management/unified/hpsum_infolibrary.html
For system firmware bundle versions 26.34 and 26.35, the HP SUM version is 5.2.0.
For system firmware bundle version 26.36, the HP SUM version is 5.3.5.
Updating rx2800 i2 Server Firmware 63