OSM Alarm Summary
OSM Alarm Summary – 541946-001 16
1.36 Invalid MSEB Configuration Record
Alarm Field Possible Values
Resource Type External Fabric
Dials Out Yes
Perceived Severity Minor
This alarm indicates that the SANMAN process found an invalid configuration
record for the Modular ServerNet Expansion Board (MSEB) in group 1, module 1,
slot 51|52.
1.37 MSEB Configuration Record Fetch Error
Alarm Field Possible Values
Resource Type External Fabric
Dials Out Yes
Perceived Severity Minor
This alarm indicates that the SANMAN process encountered an internal error
while trying to fetch the configuration record for the Modular ServerNet Expansion
Board (MSEB) in group 1, module 1, slot 51|52.
1.38 ServerNet Services Initialization Error
Alarm Field Possible Values
Resource Type External Fabric
Dials Out Yes
Perceived Severity Minor
This alarm indicates that the SANMAN process encountered an error while trying
to initialize the ServerNet services for the ServerNet switch on the external fabric.
1.39 Invalid Fabric Parameter Error
Alarm Field Possible Values
Resource Type External Fabric
Dials Out Yes
Perceived Severity Minor
This alarm indicates that the SANMAN process passed an invalid fabric
parameter to the IBC driver while trying to discover the ServerNet switch on the
external fabric.