OSM Alarm Summary

OSM Alarm Summary 541946-001 18
1.44 SMC Driver Unable to Obtain Locked Memory
Alarm Field Possible Values
Resource Type External Fabric
Dials Out Yes
Perceived Severity Major
This alarm indicates that the SMC driver could not obtain the locked memory to
satisfy a SANMAN request. The primary SANMAN processor may be running low
on memory resources.
1.45 SMC Driver Returned Error
Alarm Field Possible Values
Resource Type External Fabric
Dials Out Yes
Perceived Severity Major
This alarm indicates that the SMC driver returned an error to the SANMAN
process.
1.46 Node Plugged Into an Already Used Port of Switch
Alarm Field Possible Values
Resource Type External Fabric
Dials Out Yes
Perceived Severity Major
This alarm indicates that the local node is connected to a wrong port of the switch
on the external fabric. This port is a part of a multilane link and the other port of
the multilane link is already used by another node. Two ports of a multilane link
cannot be used to connect to two different nodes.
1.47 ServerNet Path Test Failed
Alarm Field Possible Values
Resource Type Internal Fabric
Dials Out Yes
Perceived Severity Critical
This alarm indicates that the Group Connectivity ServerNet Path Test failed on
this fabric.