OSM Alarm Summary

OSM Alarm Summary 541946-001 19
1.48 ServerNet Path Down in Group <G>, Module 1, Slot <S>
Alarm Field Possible Values
Resource Type Internal Fabric
Dials Out Yes
Perceived Severity Critical
This alarm indicates that ServerNet path between the router and the processor in
the group <G>, module 1, slot <S> is down. The exact reason is part of the repair
text.
1.49 Persistent Backpressure in Processor <P>
Alarm Field Possible Values
Resource Type Internal Fabric
Dials Out Yes
Perceived Severity Critical
This alarm indicates that persistent backpressure in the ServerNet fabric has
been detected for processor <P>.
1.50 ServerNet Router Port Error
Alarm Field Possible Values
Resource Type Internal Fabric
Dials Out Yes
Perceived Severity Major
This alarm indicates that too many router port errors have been detected. The
detailed analysis of the specific incidents is part of the repair text.
1.51 ServerNet Router 2 Port Exception
Alarm Field Possible Values
Resource Type Internal Fabric
Dials Out Yes
Perceived Severity Major
This alarm indicates that too many router 2 port errors have been detected. The
detailed analysis of the specific incidents is part of the repair text.