OSM Alarm Summary

OSM Alarm Summary 541946-001 20
1.52 Automatic Redundant Power Scrub Test Not Run
Alarm Field Possible Values
Resource Type System
Dials Out No
Perceived Severity Critical
This alarm indicates that the automatic redundant power scrub test was not run
because a ServerNet Path Test Failed alarm exists on the internal ServerNet
Fabric.
1.53 Redundant Power Scrub Test Failed
Alarm Field Possible Values
Resource Type Enclosure Module/Any Enclosure CRU
Dials Out Yes
Perceived Severity Major
This alarm indicates that the redundant power scrub check failed. The exact
cause of failure is part of the repair text of the alarm.
1.54 Power Problem
Alarm Field Possible Values
Resource Type Enclosure Module/Any Enclosure CRU
Dials Out Yes
Perceived Severity Major
This alarm indicates a power problem on the CRU.
1.55 Module Not Responding
Alarm Field Possible Values
Resource Type Enclosure Module/Any Enclosure CRU
Dials Out Yes
Perceived Severity Critical
This alarm indicates that the service processor (SP) is unable to communicate
with the module.