OSM Alarm Summary

OSM Alarm Summary 541946-001 38
1.123 Invalid Firmware Response
Alarm Field Possible Values
Resource Type Switch 3 Group
Dials Out Yes
Perceived Severity Major
This alarm indicates that an invalid response was received from the firmware on
the switch logic board.
1.124 Missing Switch Module
Alarm Field Possible Values
Resource Type Switch 3 Module
Dials Out Yes
Perceived Severity Major
This alarm indicates that this Switch module is missing while the Switch module
on the peer fabric is present.
1.125 Configuration Version Mismatch Between Neighbor
Switches
Alarm Field Possible Values
Resource Type Switch 3 Module
Dials Out No
Perceived Severity Major
This alarm indicates that the configuration of the switch logic board is down-rev
compared to the configuration of the neighbor switch logic board.
1.126 Temperature Out of Range
Alarm Field Possible Values
Resource Type Switch 3 Module, FC Disk, FCDM Power Supply or EMU,
Blade Element
Dials Out Yes
Perceived Severity Critical
This alarm indicates that the temperature of the Switch module is out of range.