OSM Alarm Summary
OSM Alarm Summary – 541946-001 40
1.131 Missing Transceiver
Alarm Field Possible Values
Resource Type Switch 3 Port
Dials Out Yes
Perceived Severity Major
This alarm indicates that the transceiver at the switch port is either missing or not
working.
1.132 Invalid Transceiver Type
Alarm Field Possible Values
Resource Type Switch 3 Port
Dials Out Yes
Perceived Severity Major
This alarm indicates that the Switch 3 PIC contains incompatible transceiver. The
types are present in the repair text of the alarm.
1.133 Switch Connected to Switch-to-Node Port of Neighbor
Switch
Alarm Field Possible Values
Resource Type Switch 3 Port
Dials Out Yes
Perceived Severity Major
This alarm indicates that the switch is connected to a node port of a neighbor
switch. The expected port is part of the repair text of the alarm.
1.134 Port Number Mismatch Between Neighbor Switches
Alarm Field Possible Values
Resource Type Switch 3 Port
Dials Out Yes
Perceived Severity Major
This alarm indicates that the cabling between neighbor switch ports is incorrect.
The repair text includes the current and expected cable connection information.