OSM Alarm Summary
OSM Alarm Summary – 541946-001 41
1.135 Neighbor Switch Ports Not Connected
Alarm Field Possible Values
Resource Type Switch 3 Port
Dials Out Yes
Perceived Severity Major
This alarm indicates that a port is not connected to a switch or NSK node but the
other ports in the group are connected.
1.136 Different Switches Connected to Ports in a Multilane Link
Alarm Field Possible Values
Resource Type Switch 3 Port
Dials Out Yes
Perceived Severity Major
This alarm is created if the port has Link alive, but a different switch is detected on
this port as compared to the switch detected on the other ports that are part of the
same multilane link.
1.137 Corrupt Firmware
Alarm Field Possible Values
Resource Type Switch 2
Dials Out Yes
Perceived Severity Major
This alarm indicates that the firmware on the ServerNet switch is corrupt.
1.138 Backup Firmware Not Same as Running Firmware
Alarm Field Possible Values
Resource Type Switch 2
Dials Out Yes
Perceived Severity Major
This alarm indicates that the backup copy of the firmware on the ServerNet switch
does not match the running firmware.