OSM Alarm Summary
OSM Alarm Summary – 541946-001 51
1.175 Missing ServerNet Switch
Alarm Field Possible Values
Resource Type Switch 2 Module
Dials Out Yes
Perceived Severity Major
This alarm indicates that the system could not detect the presence of a ServerNet
Switch on the fabric.
1.176 Invalid Fabric Setting
Alarm Field Possible Values
Resource Type Switch 2 Module
Dials Out Yes
Perceived Severity Minor
This alarm indicates that the ServerNet switch on external fabric has the same
fabric setting as the other fabric.
1.177 Invalid ServerNet Switch Control Block
Alarm Field Possible Values
Resource Type Switch 2 Module
Dials Out Yes
Perceived Severity Major
This alarm indicates that an invalid switch control block is loaded on the
ServerNet switch.
1.178 Invalid ServerNet Switch PIC Type
Alarm Field Possible Values
Resource Type Switch 2 Module
Dials Out Yes
Perceived Severity Major
This alarm indicates that the system does not detect a Single Mode Fiber (SMF)
Plug-in Card (PIC) at a port of the ServerNet switch.