OSM Alarm Summary

OSM Alarm Summary 541946-001 59
1.207 Maximum Sector Rewrites For Period Exceeded
Alarm Field Possible Values
Resource Type Disk
Dials Out Yes
Perceived Severity Major
This alarm indicates that disk has reached the maximum number of spared
rewrites allowable in 24 hours. The disk is usable, but should be tested for
hardware errors.
1.208 Uncorrectable Media Error
Alarm Field Possible Values
Resource Type Disk
Dials Out Yes
Perceived Severity Major
This alarm indicates that an uncorrectable media error has occurred on the disk
drive whose mirror is down.
1.209 Primary and Backup Paths Configured to Different Disks
Alarm Field Possible Values
Resource Type Disk
Dials Out Yes
Perceived Severity Minor
This alarm indicates that the primary and backup paths to the disk are configured
to different physical disks.
1.210 Same Physical Disk Configured as Primary and Mirror
Alarm Field Possible Values
Resource Type Disk
Dials Out No
Perceived Severity Minor
This alarm indicates that the primary and mirror drives are configured as the same
physical disk.