OSM Alarm Summary

OSM Alarm Summary 541946-001 64
1.226 SCSI Bus <N> Termination Power Failure in External
Disk Module <Module ID>
Alarm Field Possible Values
Resource Type External Disk Collection
Dials Out Yes
Perceived Severity Major
This alarm indicates that the SCSI bus <N> termination power failure has been
detected in the external disk module.
1.227 Not Communicating
Alarm Field Possible Values
Resource Type Storage Router
Dials Out Yes
Perceived Severity Major
This alarm indicates that the storage router is not communicating.
1.228 Unsupported Configuration
Alarm Field Possible Values
Resource Type Tape
Dials Out No
Perceived Severity Minor
This alarm indicates that the tape drive is connected to a SAC that is not
supported. The tape drive must be connected through a SCSI SAC, which is only
available on a PMF2 (S74000 and above), an IOMF2 or a SNDA CRU.
1.229 Storage Router Not Supported
Alarm Field Possible Values
Resource Type Tape
Dials Out No
Perceived Severity Minor
This alarm indicates that the a storage router is connected to a tape drive that
does not support a connection to the storage router.