OSM Alarm Summary

OSM Alarm Summary 541946-001 66
Section 2 OSM Alarms for HP Integrity NonStop Servers
This section describes OSM alarms that are unique to HP Integrity NonStop
NS-series servers on H06.05 (OSM T0682 H02 AAN) & later.
2.1 PE Cannot be reintegrated
Alarm Field Possible Values
Resource Type CPU
Dials Out Yes
Perceived Severity Minor
This alarm is generated when a PE cannot be reintegrated because:
a) Reintegration would halt a processor
b) PE not in a state to be reintegrated
c) memory reintegration board logic error
d) Source PE for reintegrations is down
e) Reintegrations are disabled
f) PE is in Halted State Services (HSS)
2.2 Too Many Reintegration Operations
Alarm Field Possible Values
Resource Type CPU
Dials Out Yes
Perceived Severity Major
Alarm indicates the PE was required to be reintegrated too many times in the past
24 hours.
2.3 Too many reintegration failures
Alarm Field Possible Values
Resource Type CPU
Dials Out Yes
Perceived Severity Major
Alarm is generated when the PE experienced too many reintegration failures in a
reasonably short duration.