OSM Alarm Summary
OSM Alarm Summary – 541946-001 68
2.8 Invalid Reintegration Cable Connections.
Alarm Field Possible Values
Resource Type NonStop Blade Element
Dials Out Yes
Perceived Severity Major
This Alarm is generated when not all incoming NonStop Blade Element
reintegration board cables to this NonStop Blade Element come from the same
upstream NonStop Blade Element.
2.9 Invalid Reintegration Cabling Between NonStop Blade
Complexes
Alarm Field Possible Values
Resource Type NonStop Blade Element
Dials Out Yes
Perceived Severity Major
This Alarm is generated when Not all incoming NonStop Blade Element
reintegration board cables this NonStop Blade Element come from the same
complex.
2.10 Reintegration Cable Crossover
Alarm Field Possible Values
Resource Type NonStop Blade Element
Dials Out Yes
Perceived Severity Major
This Alarm is generated when all incoming reintegration cables comes from
different sides of the same NonStop Blade Element.
2.11 NonStop Blade Complex Not Fault Tolerant
Alarm Field Possible Values
Resource Type NonStop Blade Complex
Dials Out Yes
Perceived Severity Major
This Alarm is generated when the NonStop Blade Element reintegration board
cables do not form a ring topology.