OSM Alarm Summary

OSM Alarm Summary 541946-001 69
2.12 NonStop Blade Element Not Cabled to NonStop Blade
Complex
Alarm Field Possible Values
Resource Type NonStop Blade Element
Dials Out Yes
Perceived Severity Major
This Alarm is generated when the NonStop Blade Element reintegration board
cables for the complex form a ring topology, but this NonStop Blade Element has
been excluded.
2.13 Lower/Upper Reintegration Cable Connectivity Error
Alarm Field Possible Values
Resource Type NonStop Blade Element
Dials Out Yes
Perceived Severity Major
The reintegration links connectivity to this NonStop Blade Element is not
functioning correctly.
2.14 Memory Reintegration Board Initialization Error
Alarm Field Possible Values
Resource Type NonStop Blade Element
Dials Out Yes
Perceived Severity Major
The memory reintegration board of the NonStop Blade Element could not be
initialized.
2.15 NonStop Blade Element Hardware Error
Alarm Field Possible Values
Resource Type NonStop Blade Element
Dials Out Yes
Perceived Severity Major
This Alarm is generated when a reset was performed on a NonStop Blade
Element and it failed.