OSM Alarm Summary

OSM Alarm Summary 541946-001 7
Section 1 OSM Alarms Common to HP NonStop Servers
This section describes OSM alarms that apply to all HP NonStop servers on G06.28
(OSM T0682G07^AAL) & later and H06.05 (OSM T0682 H02 AAN) & later.
1.1 Power-on Self Test Failed
Alarm Field Possible Values
Resource Type FXSA/FX2SA/CPU/E4SA SAC/FESA SAC/GESA
SAC/TRSA SAC/SS7 SAC/SWAN CLIP/SWAN 2
CLIP/ATM3SA/FSAC/SSAC
Dials Out Yes
Perceived Severity Major
This alarm is generated on the corresponding resource when the power on
self test for the hardware resource fails.
1.2 Incorrect Logical Configuration
Alarm Field Possible Values
Resource Type FXSA/FX2SA/E4SA/FESA/GESA/TRSA/CCSA/SWAN
Path/SWAN 2 Path/SWAN Adapter/SWAN 2 Adapter
Dials Out Yes
Perceived Severity Minor
This alarm is generated on the corresponding resource when its SCF
configuration is not correct. For example, when a TRSA SAC is configured as a
GESA SAC in SCF.
1.3 LBU down
Alarm Field Possible Values
Resource Type FXSA/FX2SA
Dials Out Yes
Perceived Severity Major
This alarm indicates that the FOX Logic Board Unit (LBU) has been shutdown by
the foxmon process due to excessive errors.