OSM Alarm Summary
OSM Alarm Summary – 541946-001 8
1.4 Fault State
Alarm Field Possible Values
Resource Type Enclosure Fan/ Enclosure Battery
Dials Out Yes
Perceived Severity Major
This alarm indicates a hardware problem with the corresponding enclosure fan or
enclosure battery.
1.5 Correctable Secondary Cache Errors (Excessive)
Alarm Field Possible Values
Resource Type CPU
Dials Out Yes
Perceived Severity Major
This alarm is generated when the correctable secondary cache errors on a
processor exceed a set threshold within a time period.
1.6 Correctable Secondary Cache Errors (Intermittent)
Alarm Field Possible Values
Resource Type CPU
Dials Out Yes
Perceived Severity Minor
This alarm is generated when the transient correctable cache errors on a
processor exceed a set threshold within a time period. A transient CCE is
considered to have occurred, if the secondary cache is checked for CCE every
predefined minutes for predefined hours, and the CCE count is below the
excessive CCE threshold.
1.7 Correctable Memory Error
Alarm Field Possible Values
Resource Type CPU
Dials Out Yes
Perceived Severity Minor
The generation of this alarm indicates that a correctable memory error occurred at
a particular memory slot as indicated in the repair text.