ServerNet Cluster Web
The TSM incident analysis (IA) software generates an alarm if one
external fabric has two cluster switches while the other external
fabric has only one cluster switch. After a second cluster switch is
added to an external fabric, the IA checks the peer fabric to
determine if it has two cluster switches. If, after 4 minutes, only
one external fabric has two cluster switches, the IA generates a
Missing Remote ServerNet Switch alarm. If, after 4 more
minutes, the peer fabric still does not have two cluster switches,
the IA dials out the Missing Remote ServerNet Switch alarm.
If a second cluster switch is added to the peer fabric after the
alarm is generated but before the alarm is dialed out, the alarm is
deleted and is not dialed out.
Workaround: When adding cluster switches to create a split-star
topology, connect the four-lane links for both external fabrics
within 4 minutes to avoid generating the Missing Remote
ServerNet Switch alarm. If the four-lane links cannot be
connected within 4 minutes, connect them within 8 minutes to
avoid dialing out the Missing Remote ServerNet Switch alarm.
Problem: The version of the ServerNet Cluster Manual (429153-001)
included on the G06.12 TIM CD contains a page-numbering problem
in which the section numbers increment sequentially rather than
restarting at 1. Consequently, the table of contents and index do not
indicate the correct page numbers. In addition, the appendices appear
as Appendix K through Q instead of Appendix A through G.
Workaround: Do not use the ServerNet Cluster Manual
(429153-001) included on the G06.12 TIM CD. A corrected
version of the manual (520371-001) is available from the G06.12
TIM online collection. Except for the page numbers and appendix
letters, the corrected version of the manual is identical to the
version of the manual on the G06.12 TIM CD.
To access online collections via an Internet connection:
Launch TIM.1.
Choose "Add/Remove" from the Collections menu item.2.
Select "Access Web" in the Remote Collections box.3.
Add the collections you wish to use to your list of current
collections.
4.
Expand the collections to see the documents.5.
You should use TIM Viewer Version 2.1 or higher to view this
collection. Details about the TIM viewer, Version 2.1 can be found
in Support Note S99010.