Changing the System Name of a NonStop NS2000 Series System

34. Repeat the steps in this section for the second VIO enclosure.
35. After changing the system name on the second VIO enclosure, compare the LCDs of the two
enclosures and verify that the system names match.
Power Cycle All Processors
You must power cycle the processors so that the changes you made to the VIO enclosures are
recognized by the system.
NOTE: The following steps use Integrated Light-Out 2 (iLO2) to power cycle the processors.
However, if you have physical access to the system, you can press the power button on each
processor instead.
Perform these steps for each processor on the system:
36. Using its IP address, log on to a processor through iLO2.
37. In the Integrated Light-Out 2 screen, click the Virtual Devices tab.
38. Under System Power Control, select Power Cycle and click Submit.
Change the System Name in the CLIMs
Perform these steps on every CLIM on the system. For details, see the CLuster I/O Module (CLIM)
Installation and Configuration Guide.
39. Log on to a CLIM using the HP OSM Low-Level Link.
40. In the CLIM Preparation dialog box, click the Configure check box and click OK.
41. In the Configure CLIM dialog box, change the system name in the System Name text box.
Change the portion of the iLO Hostname text box that contains the system name. Click
Configure.
42. When prompted to reset the CLIM, click Yes. When a message about a remote disconnection
appears, click OK.
43. Repeat the steps in this section for every CLIM on the system.
Change the Computer Name of the NonStop System Console
Perform these steps only if the NonStop system console is dedicated to one system, and the
computer name of the NonStop system console contains the system name.
44. Right-click My Computer and select Properties.
45. Click the Computer Name tab.
46. Click the Change button.
47. Change the system name portion of the Computer name text box to reflect the new system
name.
48. Click OK.
49. When prompted to restart the computer, click OK.
50. Click OK to close the System Properties dialog box.
6 Changing the System Name of a NonStop NS2000 Series System