Changing the System Name of a NonStop System for H-Series RVUs
103. Highlight a device that contains the old system name. Record the name and IP address that
appears in the Attributes tab of the Details pane.
104. Right-click on the device and select Actions. From the Available Actions list, select Stop
Monitoring and click Perform action.
105. In the tree pane, navigate to Monitored Service LAN Devices and select Actions. From the
Available Actions list, select the Start Monitoring action for the type of device you just stopped
monitoring. Click Perform action.
106. In the Monitored Service LAN Device dialog box, enter the IP address, the new name, and
any other required information for the device. Click OK.
107. Repeat the previous four steps for any other devices that contain the old system name.
Run SSOCLIM on all CLIMs
NOTE: Perform these steps if the system is equipped with CLIMs
108. Run the SSOCLIM command for every CLIM on the system. Typically there are two IDs, root
and user, specified for each CLIM. You need to issue the command for both IDs on each CLIM.
From a TACL prompt, issue these commands for every CLIM on the system:
TACL> SSOCLIM climname root password
TACL> SSOCLIM climname user password
Check the System Inventory
109. Take another OSM inventory of the system and compare the results to the inventory you
captured previously in Preparation.
Run SSOCLIM on all CLIMs 11