Replacing a Front Group Service LED Cable Assembly
ESD Guidelines
Figure: Working in an ESD-Protected Environment
Observe the following electrostatic discharge (ESD) guidelines whenever servicing
electronic components:
Obtain an ESD protection kit and follow the directions that come with the kit. You can
purchase an ESD kit from HP (T99247-A00) or from a local electronics store. Ensure
that your ESD wriststrap has a built-in series resistor and that the kit includes an
antistatic table mat.
●
Before you unpack a replacement CRU or FRU, place the CRU or FRU package on
the antistatic table mat and attach the grounding clip on your wriststrap to the mat.
●
When you unpack the CRU or FRU, do not cut into the ESD protective bag
surrounding the CRU or FRU. The protective bag protects the CRU or FRU and can
be reused for storing the CRU or FRU that has been replaced.
●
Before you move the CRU or FRU from the antistatic table mat, attach the grounding
clip from your ESD wriststrap to any unpainted metal surface on the CRU or FRU
frame.
●
Before you bring a CRU or FRU in contact with a system enclosure, attach the
grounding clip on your ESD wriststrap to any unpainted metal surface on the
enclosure frame.
●
When you remove a CRU or FRU from a system enclosure, first pull the CRU or FRU
partway out of the slot and then attach the grounding clip on your ESD wriststrap to
any unpainted metal surface on the CRU or FRU frame.
●
Store CRUs or FRUs that require ESD protection in ESD protective bags.●
The figure Working in an ESD-Protected Environment illustrates how to use an ESD
kit when servicing CRUs or FRUs.
●
Note: An ESD protection kit can be purchased from HP using the following order
number and part number:
Order Number: ESD-kit
Part Number: T99247-A00
Related Topic
Standard Operating Practices