Replacing an E4SA CRU

2 Verify that the line is in the STARTED state.
Use the SCF STATUS LINE command for a single line:
STATUS LINE $<line-name>
Use the SCF STATUS PATH command for an Expand multiline path:
STATUS PATH $<path-name>
The example shows the output of these commands.
To verify that a ServerNet wide area network (WAN) concentrator and its
associated WAN subsystem IOPs and communications lines are started:
1 Verify that the SWAN concentrator is in the STARTED state.
Use the SCF STATUS ADAPTER with the SUB ALL option:
STATUS ADAPTER $ZZWAN.#<adapter-name>, SUB ALL
The SUB ALL option displays status information for the ADAPTER object
and its subordinate objects.
The example shows the output of this command.
2 Verify that the WAN subsystem IOPs are in the STARTED state.
Use the SCF STATUS DEVICE command:
STATUS DEVICE $ZZWAN.#<device-name>
The example shows the output of this command.
3 Verify that the lines are in the STARTED state.
Use the SCF STATUS LINE command for a single line:
STATUS LINE $<line-name>
Use the SCF STATUS PATH command for an Expand multiline path:
STATUS PATH $<path-name>
The example shows the output of these commands.
If an object is not in the STARTED state, check the event log using the OSM or TSM
Event Viewer.
Refer to the Operator Messages Manual for cause, effect, and recovery information for
event messages.