Replacing an Internal Disk Drive CRU
Resetting and Verifying a Mirrored Disk Drive
Using SCF
Follow these instructions to reset and verify a mirrored disk drive. In this example, the
$DATA17 mirror drive has just been replaced and is being prepared for a revive
operation.
Use the SCF RESET DISK command; then use the SCF STATUS DISK command to
verify that the disk drive is in the STOPPED state with the substate DOWN.
TACL>SCF RESET $DATA17
->STATUS $DATA17-*
STORAGE - Status DISK \TOYS.$DATA17-*
LDev Path Status State Substate Primary
Backup
PID
PID
88 PRIMARY ACTIVE STARTED 1,266
0,282
88 BACKUP INACTIVE STARTED 1,266
0,282
88 MIRROR INACTIVE STOPPED DOWN 1,266
0,282
88 MIRROR-BACKUP INACTIVE STOPPED DOWN 1,266
0,282
->