Upgrading to S7600 PMF CRUs

Upgrading to S7600 PMF CRUs
Use this procedure to upgrade both PMF CRUs in an enclosure to S7600 PMF CRUs.
S7400 PMF CRUs can be upgraded online, but S7000 PMF CRUs must be upgraded
offline. See PMF CRUs That Can Be Upgraded Online and That Can Coexist
Permanently in Mixed Systems.
See Change History for changes made to this procedure.
Notes:
Do not attempt to upgrade to unsupported configurations.
IOMF and IOMF 2 CRUs are supported on S7600. IOMF 2 is needed to take
advantage of ServerNet II.
IOMF and IOMF 2 CRUs can coexist briefly in an enclosure for online upgrade.
For performance reasons, both IOMF CRUs in an enclosure must be IOMF or
IOMF 2 CRUs.
Preparing for the Upgrade
1 If you are upgrading S7000 PMF CRUs to S7600 PMF CRUs, a power shelf
and two power supplies must be installed in each processor enclosure by a
trained service provider. Contact your service provider for more details.
2 If you are upgrading from S7000 (NSR-W) to S7600 (NSR-E), you must
change the processor type entry in the CONFTEXT file ALLPROCESSORS
statement to NSR-E before you replace the PMF CRUs. You can specify
only one processor type. S7000 cannot be in a system with mixed processor
types.
After changing the CONFTEXT file, you must perform all required DSM/SCM
requests to create a new SYSnn. System load of the new SYSnn is required
after the new hardware is installed. Failure to change the processor type
causes an immediate %100441 halt when the new SYSnn is loaded. See the
appropriate G06.24 or later Release Version Update Compendium for
migration and fallback details.