Upgrading to S7600 PMF CRUs
3 Upgrading the SEBs to MSEBs is not a requirement for S7600. If you are
installing MSEBs and replacing the interconnecting ECL cables with serial
copper or fiber-optic cables, you can perform these upgrades either offline or
online on one fabric at a time.
Note: If you are replacing SEBS and ECL cables prior to installing the
G06.17 or later RVU, use OSM software or TSM server product version
T7945ABB (from G06.16) and TSM client 2002B T8154ABB to replace them
on one fabric at a time. These products bring down the selected SEB or
MSEB and all SEBs or MSEBs that are cabled to it. On earlier versions of
TSM, you must perform separate operations to bring down both ends of a
link before replacing a cable.
To replace the SEBs on one fabric at a time, run a separate replacement
procedure for each SEB to be replaced (you can use OSM replace actions
or Replace SEB or MSEB guided procedures):
Start the procedure to replace one of the SEBs.1.
Run the procedure until you are prompted to Replace the SEB. Then
start a new copy of the procedure for another of the SEBs, continuing
up to the manual replace prompt.
2.
Repeat Steps 1 and 2 until the procedures for all the SEBs to be
replaced in one fabric display the manual replace message.
3.
Physically remove all of the selected SEBs and ECL links, and install
the MSEBs and new links.
4.
Complete one procedure. Allow this copy of the procedure to complete
before repeating for each of the other replacements.
5.
Replace the SEBs and cables in the other fabric, using this procedure, after
verifying that the newly installed MSEBs and links work properly.
See NonStop S-Series Topologies for cabling information.
Related HotStuffs
These S74000 Hotstuffs also apply to S7600:
HS02633 NSK T1075AAM PMF UPGRADE TO S74000●
For G06.10 RVU, when a PMF CRU is upgraded online and a tape device
is configured to that PMF CRU, the GRT might fail, the peer processor will
not be able to access the new PMF CRU adapter, subsequent controller
downloads to all SACs of the adapter will fail, and none of the disk and tape
paths through the adapter will come up. See HS02633 for the workaround
and fix.
HS02519D NSK OPN T8606D30/D42/D46/G06 NONSTOP TM/MP●