Upgrading to S76000 and S86000 PMF CRUs

SEB or MSEB and all SEBs or MSEBs that are cabled to it. On earlier
versions of TSM, you must perform separate operations to bring down both
ends of a link before replacing a cable.
To replace the SEBs on one fabric at a time, run a separate replacement
procedure for each SEB to be replaced (you can use OSM replace actions
or Replace SEB or MSEB guided procedures):
Start the procedure to replace one of the SEBs.1.
Run the procedure until you are prompted to Replace the SEB. Then
start a new copy of the procedure for another of the SEBs, continuing
up to the manual replace prompt.
2.
Repeat Steps 1 and 2 until the procedures for all the SEBs to be
replaced in one fabric display the manual replace message.
3.
Physically remove all of the selected SEBs and ECL links, and install
the MSEBs and new links.
4.
Complete one procedure. Allow this copy of the procedure to complete
before repeating for each of the other replacements.
5.
Replace the SEBs and cables in the other fabric, using this procedure, after
verifying that the newly installed MSEBs and links work properly.
The SEBs in slot 53 and slot 54 of all processor enclosures, the IOMF CRUs
in I/O enclosures, and the SEB-to-IOMF CRU cables can remain the same.
2 If S7000 PMF CRUs are being upgraded to S76000 or S86000 PMF CRUs,
a power shelf and two power supplies must be installed in each processor
enclosure by a trained service provider. Contact your service provider for
more details.
3 If you are upgrading from S7000 (NSR-W), you must change the processor
type entry in the CONFTEXT file ALLPROCESSORS statement before you
replace the PMF CRUs. Enter NSR-X (for S76000) or NSR-H (for S78000).
You can specify only one processor type. S7000 cannot be in a system with
mixed processor types.
After changing the CONFTEXT file, you must perform all required DSM/SCM
requests to create a new SYSnn. System load of the new SYSnn is required
after the new hardware is installed. Failure to change the processor type
causes an immediate %100441 halt when the new SYSnn is loaded. See the
appropriate G06.24 or later Release Version Update Compendium for
migration and fallback details.
Required Tools and Documentation
For this upgrade procedure, you need:
G06.nn Software Installation and Upgrade Guide (G06.16 or a later version).