Upgrading to S76000 and S86000 PMF CRUs
The appropriate OSM action or guided procedure for replacing PMF CRUs. See
Guided Procedures for more information.
●
Upgrading to S76000 and S86000 PMF CRUs
You must perform these steps in exactly the order listed here, even if you have
successfully performed previous upgrades by doing these steps in a different order.
1 Install the G06.16 SUT. For further instructions, see the G06.16 Software
Installation and Upgrade Guide (or a later version). For those migrating from
pre-G06.16 release version updates (RVUs), the guide also describes a step
needed after the SUT is installed.
2 Update service processor firmware.
3 Update processor boot code.
4 Run the ZPHIRNM program.
5 Load the G06.16 RVU.
6 Update the SCSI boot code and perform post-load steps as needed.
7 Use the OSM Service Connection or the TSM Service Application to check
for alarms and verify that the system is operating properly. Resolve any
problems before you install new hardware.
8 Replace one PMF CRU by using the OSM action or guided replacement
procedure.
When the procedure prompts you to physically replace the PMF CRU, a help
button appears that allows you to access detailed instructions.
Caution: Verify the Gemini daughter boards are fully seated before
installing the PMF CRUs. See Tech Bulletin TB20051B.
9 Verify that the PMF CRU is operational, and then immediately replace the
other PMF CRU in the same enclosure by using another OSM action or
guided replacement session.