Upgrading to S7800 PMF CRUs

Upgrading to S7800 PMF CRUs
Use this procedure to upgrade both PMF CRUs in an enclosure to S7800 PMF CRUs.
See Change History for changes made to this procedure.
S7400 and S7600 PMF CRUs can be upgraded online, but S7000 PMF CRUs must be
upgraded offline. See
NTL customer site: PMF CRUs That Can Be Upgraded Online and Coexist
Permanently in Mixed Systems.
NTL employee site: PMF CRUs That Can Be Upgraded Online and Coexist
Permanently in Mixed Systems.
Notes:
Do not attempt to upgrade to unsupported configurations.
IOMF and IOMF 2 CRUs are supported on S7800.
IOMF 2 CRUs connected through MSEBs are needed to take advantage of
ServerNet 2.
IOMF and IOMF 2 CRUs can coexist in an I/O enclosure for a brief period while
performing an online upgrade. For performance reasons, both IOMF CRUs in an
enclosure must be IOMF or IOMF 2 CRUs.
You cannot reconfigure a Tetra 8 to a Tetra 16 topology online. You must
perform this expansion offline.
Caution: Ask your service provider to verify the daughter board connectors on the
PMF CRU are fully seated before installing the CRU. Instructions are in Technical
Bulletin TB20051B. This affects S7800, S76000, S86000, S78000, and S88000.
Preparing for the Upgrade
1 If you are upgrading from S7000 to S7800 PMF CRUs, a power shelf and
two power supplies must be installed in each processor enclosure by a
trained service provider. Contact your service provider for more details.