Upgrading to S7800 PMF CRUs

needed to replace them on one fabric at a time. See Upgrading SEBs to
MSEBs on One Fabric at a Time.
Required Tools and Documentation
For this upgrade procedure, you need:
The G06.nn Software Installation and Upgrade Guide (G06.16 or later RVU).
The appropriate OSM action or guided procedure for replacing PMF CRUs.
Required Software
S7800 was introduced for G06.23. It is supported on G06.24 and later, on G06.23 with
one SPR, and on G06.16 through G06.22 with other OSM or TSM SPRs. G06.16
through G06.23 require SPRs to allow scan-string collection after a hardware error
freeze (HEF).
OSM Service Connection Suite (T0682)
G06.23: T2728AAJ (OSM Service Provider)
G06.16 through G06.22:
OSM: T2723AAD (OSM Connection Library)
T2724AAD (OSM Provider Interface Library)
T2725AAD (OSM Configuration)
T2726AAD (XML API)
T2727AAD (OSM CIMOM)
T2728AAD (OSM Service Provider)
T2730AAD (OSM Event Viewer)
T2751AAD (OSM Web-Based Suite)
T2752AAD (OSM Application Suite)
TSM: T7945ABL (TSM Server)
T8154ABG (TSM Client)
Caution:
To upgrade the boot millicode to T7892ABD or later using the online update
function, you must have the G06.24 version of the TSM server (T7945ABN) or
later or all G06.24 OSM server based SPRs and their prerequisites configured
and running. See the Software Installation and Upgrade Guide (G06.24 or later)
and Hotstuff HS02865 for details. If you attempt to do an online update without
these, the processors will halt. When migrating from an earlier RVU to G06.24 or
later, you must use a hard reset as described in Step 4b or install the SPRs first.
After G06.24 or SPRs T2728AAL (OSM) or T7945ABN (TSM) are installed and
running, the boot code can be updated online. The online bootcode update