Enclosures Missing in OSM or TSM Management Windows

Enclosures Missing in OSM or TSM
Management Window
Symptom
After a System Discovery, some enclosures are not displayed.
Version
All.
Problem
You have inserted, replaced, or moved a PMF CRU or IOMF CRU
configured for a topology that does not match the topology of this system.
This problem can also occur in a system configured as a Tetra 16 topology
if a PMF CRU or IOMF CRU has been moved from the outer tetrahedron to
the inner tetrahedron.
Group numbers for inner and outer tetrahedrons are listed here.
Inner Tetrahedron
Processor
Enclosure
I/O Enclosure
01 11 12 13 14 15
02 21 22 23 24 25
03 31 32 33 34 35
04 41 42 43 44 45
Outer Tetrahedron
Processor
Enclosure
I/O Enclosure
05 51 52 53 54 55 56 57 58 59
06 61 62 63 64 65 66 67 68 69
07 71 72 73 74 75 76 77 78 79
08 81 82 83 84 85 86 87 88 89