Enclosures Missing in OSM or TSM Management Windows

Fix
1 Verify that the affected enclosure is powered on.
2 Using the OSM or TSM Low-Level Link Application, check the
Topology attribute of all PMF CRUs and IOMF CRUs in your
system. Begin with the one that was most recently inserted.
System discovery is required.
3 If the Topology attribute of any PMF CRU or IOMF CRU does not
match the topology of your system, reset the topology of your
system using one of the OSM or TSM Low-Level Link Application
Set Topology actions.
4 Verify that the Topology After Next Power Cycle attribute of the
affected CRU has changed.
5 Power off the system.
6 Power on the system again.
7 Use the OSM or TSM Low-Level Link Application to verify the
change.
For more information on changing and verifying system topology, see:
OSM or TSM online help
OSM User's Guide or TSM Online User Guide