Troubleshooting the SLSA Subsystem
This error is returned when the object on which the test action was requested has not been
configured. To recover from this error, configure the object by using SCF commands and
then retry the test action.
Error ID 6000018
This error is returned when no ServerNet addressable controllers (SACs) are found on the
CCSA adapter. A SAC resides on a CCSA as a plug-in card (PIC). To recover from this
error, make sure that at least one PIC is properly inserted in the CCSA.
Error ID 6000019
This error is returned when a non type 510 file is specified. To recover from this error, make
sure that the correct file name is specified and then retry the test action.
Error ID 6000020
This error is returned when the specified firmware file does not contain firmware code for
the type of adapter on which the Firmware Update action was initiated. To recover from this
error, make sure the correct firmware file is specified and then retry the Firmware Update
action.
Error ID 6000022
This error is returned when an unexpected response is received from a LAN monitor
(LANMON) process. Retry the test action.