Troubleshooting the SWAN Concentrator and WAN Subsystem

Manufacturing Naming Conventions
Manufacturing uses a naming convention for processes and devices that relates logical
names to the physical location of devices.
The following table describes this naming convention. This information is also included in
the $SYSTEM.ZSYSCONF.SCF0000 file.
Type of Object Convention Example Description
Disk drives $D<cabid><slot> $D3217 Second I/O
enclosure attached
to third processor
enclosure, slot 17
Tape drives $T<cabid><slot> $T0150 First processor
enclosure, slot 50
LAN adapters E<cabid><slot> E0153 First processor
enclosure, slot 53
Logical interfaces
(LIFs)
L<cabid><portid> L018 First processor
enclosure, slot 53,
port 0
TCP/IP processes $ZB<cabid><portid> $ZB018 TCP/IP process for
the above LIF
Telnet processes $ZN<cabid><portid> $ZN018 Telnet process for
the above TCP/IP
process
Listner processes $ZP<cabid><portid> $ZP018 Listner process for
the above TCP/IP
process
TFTP server
processes
$ZF<cabid><portid> $ZF018 TFTP server process
for the above TCP/IP
process
WANBoot processes $ZW<cabid><portid> $ZW018 WANBoot process
for the above TCP/IP
process
SNMP trap
multiplexer
processes
$ZTMX1, $ZTMX2,
and so on
$ZTMX1
SNMP agent
processes
$ZTMXA, $ZTMXB,
and so on
$ZTMXA