Troubleshooting the SWAN Concentrator and WAN Subsystem

Error ID 4002014
This error is returned if a previously initiated test action is still running in the selected CLIP.
To recover from this error, wait until the previously initiated test action is finished and then
retry the test action.
Error ID 4002015
This error is returned if the firmware object code file attribute (KERNELCODE) for the
SWAN concentrator is invalid. The recovery for this error is the same as for Error ID
4002013.
Error ID 4002016
This error is returned if the selected CLIP is inaccessible. To recover from this error, verify
that the SWAN concentrator is configured properly, correct any configuration errors, and
then retry the test action. See Verifying a SWAN Concentrator Configuration for more
information.
Error ID 4002017
This error is returned if the test action could not be downloaded to the selected CLIP. This
problem may occur because another test action is currently running in the CLIP. To
recovery from this error, wait until the previously initiated test action is finished and then
retry the test action.
Error ID 4002018
This error is returned if the test action could not be performed because its associated DIAG
task file could not be found. To recover from this error, make sure that the file D8155P00
exists in the current $SYSTEM.CSSnn subvolume and then retry the test action.
Error ID 4002027
This error is returned if the primary path to the selected CLIP is down. To recover from this
error, verify that the primary path to the CLIP is configured properly, correct any
configuration errors, and then retry the test action. See Verifying a SWAN Concentrator
Configuration for more information.
Error ID 4002028
This error is returned if the backup path to the selected CLIP is down. To recovery from this
error, verify that the backup path to the CLIP is configured properly, correct any
configuration errors, and then retry the test action. See Verifying a SWAN Concentrator
Configuration for more information.