Troubleshooting the SWAN Concentrator and WAN Subsystem
Error ID 4002029
This error is returned if both the primary and backup paths to the selected CLIP are down.
To recover from this error, verify that the SWAN concentrator is configured properly, correct
any configuration errors, and then retry the test action. See Verifying a SWAN Concentrator
Configuration for more information.
Error ID 4002030
This error is returned if a hardware test on the selected CLIP failed because of a CLIP
hardware fault. There is no recovery for this error. You must replace the SWAN
concentrator.
Error ID 4002031
This error is returned if at least one of the power-on self-tests (POSTs) failed on the
selected CLIP because of a CLIP hardware fault. There is no recovery for this error. You
must replace the SWAN concentrator.
Error ID 4002032
This error is returned if the OSM Service Connection or the TSM Service Application was
unable to obtain power-on self-test (POST) results because the selected CLIP could not be
accessed. There is no recovery for this error. You must replace the SWAN concentrator.