HP Integrity rx1600 Operation and Maintenance Guide
Chapter 6
Troubleshooting
Identifying and Diagnosing Hardware Problems
109
T - Text mode
Enter new value, or [Q] to Quit:
Step 6. To decode the blinking state of system LED, review the entire SEL and look at events with alert level 3 and above.
For example:
Log Entry 24: 14 Feb 2003 15:27:02
Alert Level 3: Warning
Keyword: Type-02 1b0800 1771520
Hot Swap Cage: SCSI cable removed
Logged by: BMC; Sensor: Cable / Interconnect - SCSI ChExt Cable
Data1: Device Removed/Device Absent
0x203E4D0AC6020220 FFFF0008F61B0300
Log Entry 73: 00:00:12
Alert Level 3: Warning
Keyword: Type-02 050301 328449
The server's built-in sensors have detected an open chassis door.
Logged by: BMC; Sensor: Physical Security - Chassis Open
Data1: State Asserted
0x200000000C020570 FFFF010302050300
NOTE More detailed information on the system logs is presented under Chapter 5, “Utilities.”
Systems without a Management Processor Card
The system LED states operate the same with systems having the optional management processor card.
Table 6-3 Power and System LED States
Power LED System LED State
Off Off Off
On (green) Solid green Running
On (green) Blinking green Booting or running code other than
operating system (boot or diagnostic).
On (green) Blinking yellow (1/sec.) Attention indication
On (green) Blinking red (2/sec.) Fault indication