Command Line Interface
The baseboard management controller (BMC) is accessable by means of the BMC console commands or command line
interface (CLI). The commands are similiar to the management processor (MP) commands but are silghtly less interactive.
Detailed information on the CLI commands is provided under Chapter 5, “Utilities.”
Command Line Interface Menu
The command line interface (CLI) provides the following menu selections:
date: Date display
help: List available commands
ipmi: Send IPMI cmd
loc: System locator LED
passwd: Change password
pc: Power control
pr: Power restore policy
ps: Power status
rs: System reset (through RST signal)
sl: Show logs
sr: Display firmware revisions
tc: System reset (through INIT signal)
exit: Exit
Troubleshooting Example Using CLI
This example uses the cli and the SEL to display error messages indicating that no memory is installed.
cli>sl e
# Sev Generator/Sensor Description Event ID Data, Timestamp
---- - ---------------- ------------ ----------- --------------------------
Flashing Red Green Red Green Red 12V out of range
(power supply
interface fault)
View the SEL for additional
information. If the power
supply interface has failed it is
necessary to replace the base
unit.
Table 6-21 Power Supply Errors (Continued)
System
LED