HP Integrity rx1600 Operation and Maintenance Guide
Appendix B
193
B Event, Error, and Warning Messages
This appendix contains event, error and warning information for the hp Integrity rx1600 Server system:
• Extensible Firmware Interface (EFI) error and warning messages
• System Event Log (SEL) and Forward Progress Log (FPL) Entries
EFI Error and Warning Messages
EFI error and warning messages are displayed on the console as part of the boot process. They can also be retrieved via the
info warnings EFI command.
Table B-1 EFI Error and Warning Messages
Error
Number
Error/Warning Message Solution
2 Insufficient resources to assign to one or more I/O
devices
Incorrect I/O configuration. Contact the HP
Support center for assistance.
4 Unexpected hardware I/O configuration
Incorrect I/O configuration. Contact the HP Sup-
port center for assistance.
7 No Baseboard Management Controller (BMC)
installed in platform
Ensure the BMC ROM is installed; update BMC
firmware
8 BMC cannot be accessed Check system logs for errors. Replace the base
unit.
9 One or more BMC ports failed Communication with the BMC failed. Check
power. Replace the base unit.
10 BMC system event log is full Clear SEL
11 Platform SCR is bad Contact the HP Support center for assistance.
12 Set time to BMC SEL failed Communication with the BMC failed. Replace
the base unit.
13 SEL get info failed Communication with the BMC failed. Replace
the base unit.
14 Initial BMC SEL event failed Communication with the BMC failed. Replace
the base unit.
15 Update of BMC buffered data failed Communication with the BMC failed. Replace
the base unit.
16 All Advanced Configuration and Power Interface
(ACPI) BMC ports bad
Communication with the BMC failed. Replace
the base unit.
17 Read error on BMC token Communication with the BMC failed. Replace
the base unit.